Embryo-Transfer-Katheter – single-piece
In this single-lumen universal catheter a more stiff and rigid material at the proximal sheath of the catheter is used in combination with a smoother and thinner material at the distal tip.
Product description | Product code | Unit |
---|---|---|
Emtrac A | 4219 A | 25 piece |
Emtrac D | 4219 D | 25 piece |
Emtrac C | 4219 C-200 | 25 piece |
4219 C-240 | 25 piece |
Product facts and notices
- The marking (6 to 7 cm from the distal orifice) together with the positioner facilitates the precise insertion of the catheter.
- The usage of the positioner ensures a precise insertion according to the previously measured depth of the uterus.
- The device may also be used for intrauterine inseminations where a smooth and thin ending of the catheter is desired.
- Thin embryo-transfer-catheter, offering a reliable insertion through the cervix.
- A Luer-Lock allows an easy to use adaption to common syringes.
Directions for use:
- Adjust the positioner according to the previously determined depth of the uterus.
- Subsequently insert the Emtrac A, loaded with embryos.
- After having reached the optimal position, release the embryos.
- Following the complete expulsion of the embryos inspect the Emtrac A to verify embryo release.
Notice:
The medical product carries a CE certificate, is gamma irridated and tested for endotoxines. The device is intended for single use.
The embryo-transfer catheters are manufactured at Gynétics, Belgium and are subject to a quality management system according to ISO 13485:2003 und ISO 9001:2008
- The marking (6 to 7 cm from the distal orifice) together with the positioner facilitates the precise insertion of the catheter.
- The usage of the positioner not only ensures a precise placement but also provides protection against injuries at the fundus.
- The Emtrac D may also be used for intrauterine inseminations where a smooth and thin ending of the catheter is desired.
- A Luer-Lock allows an easy to use adaption to common syringes.
Directions for use::
- Adjust the positioner according to the previously determined depth of the uterus.
- Subsequently insert the Emtrac D, loaded with embryos.
- After having reached the optimal position, release the embryos.
- Following the complete expulsion of the embryos inspect the Emtrac D to verify embryo release.
Notice:
The medical product carries a CE certificate, is gamma irridated and tested for endotoxines. The device is intended for single use.
The embryo-transfer catheters are manufactured at Gynétics, Belgium and are subject to a quality management system according to ISO 13485:2003 und ISO 9001:2008
Advantages:
- The especially rounded tip is designed for a gentle, atraumatic insertion which thereby protects the mucosa of the cervix and the emdometrium.
- The markings on the catheter ensure a precise positioning within the cervix or the uterus.
- The Emtrac C is adapted for the Guiding probe – together they result in a affordable and reusable transfer system for daily use.
- A metal strenghener inside of the catheter alleviates the handling.g.
- The Emtrac C may also be used for intrauterine inseminations where a smooth and thin ending of the catheter and a distal orifice are desired.
- A Luer-Lock allows an easy to use adaption to common syringes.
Directions for use:
- Adjust the positioner according to the previously determined depth of the uterus.
- Subsequently insert the Emtrac C, loaded with embryos.
- After having reached the optimal position, release the embryos.
- Following the complete expulsion of the embryos inspect the Emtrac C to verify embryo release.
Notice:
The Emtrac C carries a CE certificate, is gamma irridated and tested for endotoxines. The device is intended for single use.
The embryo-transfer catheters are manufactured at Gynétics, Belgium and are subject to a quality management system according to ISO 13485:2003 und ISO 9001:2008.